Products

DIRECT DRIVE:

Pro 1000

Pro 1200

Pro 1200HV

Pro 2000

SLIDE-IN:

Rebel

Commander

Commander HO

Triton DS

Triton GS

Triton LS

AIR DUCT & FURNACE CLEANING

Ultralite Series

Cyclone

Accessories

Racks

Tanks

Reels

Wands & Tools

Misc. Accessories




Commander H.O.

Overview Features Specifications Standard Package Optional Equipment
 
Commander H.O. Internal features and benefits:

(Select a number to see a brief explaination of the feature)

 

Right Side View:

1.)  (PN# A405-1L) Front Console w/Partition Baffle: (face panel) One of the most important feature of any slide in system, but the most over looked is the Partition Baffle.   The Partition Baffle is responsible in preventing the re-circulation of heated air generated by the engine & heat exchange system.   All White Magic slide-ins have been designed with this feature in mind.  The signature series partition baffles are connected by gasket materials to the air intake of the engine housing to insure proper air flow of the machine is achieved.

2.)  (PN# J345) Engine:  (28 HP KOHLER AEGIS® Liquid Cooled Engine) KOHLER AEGIS® Engines are designed with overhead -valves, exclusive hydraulic valve lifters, full pressure lubrication.

3.)  (PN# A103-50) Pump Disengagement Clutch: This allows the machine to quickly go between carpet cleaning operations to flood extraction work.   With just a flip of the switch the pump clutch disengages, stopping the pump from functioning.  The clutch & belts are covered by an aluminum safety guard,  protecting the operator and machine from harm.

4.)   (PN# A103) CAT PUMP®  5CP Pump:  Far superior from any other pump manufacturers,  CAT PUMP®  delivers outstanding reliability and performance.  Mounted in the machine high above all other components allows for quick and easy service of the pump.  While performing service the pump does not need to be un-bolted or readjusted, all service can be done in place.  This saves hours of down time and expense to the equipment owner.

5.) (PN# A103-70) Pulsation Hose:  As the ceramic plungers of the CAT Pump push water into the system, a vibration is given off.  The pulsation or vibration is absorbed helping prevent premature failure of fittings and components.

6.) (PN# WB300) Water Box: Constructed from Stainless Steel, the water box provides the incoming water to the pump.  The box can contain a max. of  (2) gallons of water and has a whole host of features.  Located above all of the other components the water box is hung in place and secured with only (1) ¼” 20 bolt, allowing the box to be quickly removed if service is necessary.   The water box has (4) easy to remove thumb-screws that holds down the gasketed cover, preventing water from spilling over on to the machine.   The water box also has overflow protection, filtered input and allows for simple winterization of the machine in cold weather climates.

7.) (PN# B098) Water Pressure Reducer:  Located on the input of the water box the pressure reducer assures that the input water pressure is consistent, for extra protection of the internal float valve.

8.) (PN# A1010)  ROOTS  47 Blower: White Magic has selected DRESSER ROOTS as our exclusive vendor for Vacuum Blowers. The Commander is outfitted with the ROOTS  47 blower providing 460 CFM and 14”Hg of vacuum lift. These blowers are capable of producing exceptional performance for all aspects of upholstery cleaning to water extraction.  The dual lobe blower design is far superior and more reliable to the new tri-lobe blower designs available in the cleaning industry.

9, 11.) (PN# J735,J740,J745)  Progressive Silencing System: White Magic engineers have worked tirelessly to maximize performance without restricting airflow.  The Progressive Silencing system works by stepping down the noise generated by the carpet cleaning system at specific locations throughout the machine.

10.) (PN# MF2100)  Frame Assembly:  Constructed from heavy gauge steel, the frame also provides easy lifting with its built in fork lift pads.

12.) (PN# B0786) 3” Muffler Clamp: High Quality, Heavy Duty muffler clamps hold the exhaust system in our truckmounted cleaning systems.

13.) (PN# B0085) Blower Oil Lever Sight Tube: Made of High Quality TYGON Tubing, this sight tube provides easy views of the blower oil level.

14.) (PN# G036) Blower V-Belts: (2) 36” Industrial Strength V-Belts drive your vacuum blower.

15.) (PN# G038) Pump V-Belts: (2) 38” Industrial Strength V-Belts drive your high pressure pump.

16.) (PN# J710) Exhaust Pipe: Directs exhaust gasses out of the front of your machine and out of the van.

Left Side View:

1., 19)  (PN# HE2200-1, HE2200-2) Heat Exchange System:  Making up the heart of the Heatsmart Technology is our double barrel heat exchanger.   Constructed using White Magic exclusive High Efficiency Finned Copper Coil, this coil is far superior to other coil designs found elsewhere in the United States.  The heat exchanger is designed to maximize both airflow and heat transfer. As the water flows through the heat exchanger it enters at the coolest point and exits the heat exchanger at the hottest point.  This is commonly referred to as Reverse Flow.

2.)  (PN# B135P) Pressure Relief Valve:  This valve is factory set to prevent over pressurization of the machine.  When the machine reaches its setting the valve opens to relieve excess pressure being developed by the pumping system. This valve allows the operator to adjust the pressure up to 1200 PSI for tile and grout cleaning.

3, 4, 5.)  (PN# A380, A381, A383) Vacuum Actuators:  Opens and closes the Heat Diverters to maintain and control water temperature.

6, 8 - 12, 20.)  (PN# H011, H0155, H016, H017) Stainless Steel Braided Hoses: White Magic uses only Stainless Steel high-pressure hoses to interconnect the systems solution and pumping system.

7.)  (PN# H425) Flexible Hose, Air Input: Connects the Air Cleaner on your machine to the fresh outside air.

13.)  (PN# H013) Chemical Jug Input Line:  Connects your chemical pump to your mixed chemical in the chemical jug.

14.)  (PN# A140M) Vacuum Solenoid:  As the temperature reaches its predetermined setting established by the operator, the Temperature Sensor sends an electrical signal to the vacuum solenoid which activates the Vacuum Pods to open and close the Heat Diverters to maintain the desired operating solution temperatures.

15.)  (PN# J790) Tube Clamp:  Connects your chemical pump to your mixed chemical in the chemical jug.

16.)  (PN# J720) Engine Exhaust Diverter:  This component operates by directing the flow of hot gases produced by the engine. During operation of the machine the heat generated by the engines exhaust will flow into the heat exchange system to heat the cleaning solution.  Once the cleaning solution has reach the pre-determined temperature set by the operator the temperature sensor will activate the vacuum diverter control closing the Exhaust Diverter preventing the hot gases from entering the heat exchange systems.  The Heat Diverters internal components are made from Stainless Steel and are nickel-plated to extend life of thediverter.

17.)  (PN# J715) Blower Exhaust Diverter:  Working in conjunction with the engine exhaust diverter is White Magic’s exclusive blower exhaust diverter.  This diverter protects the system from over heating.   After the engine exhaust diverter has closed, and if the solution temperature continues to rise, the blower exhaust diverter will then activate, preventing any of the heat generated by the blower from entering the Heat Exchange System.   This is an exceptional feature for water recovery operations.  When the machine is placed into water recovery mode both the Engine Exhaust Diverter and Blower Exhaust Diverter are activated.  This prevents any heat generated from entering the heat exchange system, allowing the machine to run continuously for hours with no water in the system.

18.)  (PN# D0029B) Heavy Duty Spring:  Assists the blower diverter in closing while under a vacuum load.

21.)  (PN# J0347) High Temperature Kill Switch:  This safety feature protects the operator, bystanders and the machine from dangerous overheating of the systems water temperature rating.  This Safety Kill Switch will shut the machines engine down if the solution temperature exceeds 275°F.  If this occurs the operator can quickly determine the cause or the shut down by looking at the indicator lights on the face panel of the machine.

 

Click Here To Return to top of page...

*All features subject to change without notice. All specifications are subject to change without notice. Major components specifications are manufacturers maximum ratings. System is de-rated for maximum life. Engine and blower are used to 70-80% capacities. System pressure is set at 1200 PSI.